Skip to main content

Slide Technical Specifications
  Reactor 85 Mk II Reactor 300 Reactor 650 Reactor 5000
         
Nominal contaminant destruction, lbs/day 10 20 40 200
Area of influence** square feet 600 1500 3000 6000
Continuous Operation YES YES YES YES
Air flow ft3/min 100 239 665 2,000
Water flow (GPM) 5 gpm 6 gpm 8 gpm 15 gpm
Fan speed (RPM) 1750 rpm 2950 rpm 1600 rpm 1600 rpm
Monthly BioOx Media requirement*** 250 ml / 8.45 oz 500 ml / 16.9 oz 1000 ml / 33.8 oz 3785 ml / 1 gal
Container Vol (G) 10 G 40 G 90 G 200 G
Voltage 110 110 110 110
Frequency 60 60 60 60
Amperage (A) 1A 1A 1A 1A
Power consumption 24 Watts 115 Watts 115 Watts 600 Watts
Dimensions (D x H) 13" x 25" 21" x 45" 29" x 54" 41" x 66"
Noise levels 34 db 55 db 52 db 53 db
Dry Weight 16 lbs 38 lbs 77 lbs 190 lbs

* Discounts available for purchases of multiple units. Finance options also available.

** A larger unit may be necessary if severe levels of continuous contamination are sustained regardless of area of influence.

*** BioOx Media requirements can fluctuate with levels and types of contamination, and BioOx Media concentration. A booster of twice the monthly amount is required at startup.

Filtering Method

– Convection
– Molecular charge attraction
– Bio-oxidation

Filtering Abilities

Captures all sized particles including but not limited to allergens, bacteria, odors, viruses, germs, cigarette smoke, all forms of chemical and biological fumes.

Electrical and Operating Requirements

Line voltage: 100–240V AC
Frequency: 60Hz, single phase
Operating temperature: 50° to 95° F (10° to 35° C)
Relative humidity: 0% to 100%

Installation and Maintenance

Installation and set up for each unit is under an hour. Depending upon your pollution levels, maintenance of the units is required every one to three months. Addition of BioOx Media is required every month. And, a constant water level must be maintained.

Electrical and Operating Requirements

Line voltage: 100–240V AC
Frequency: 60Hz, single phase
Operating temperature: 50° to 95° F (10° to 35° C)
Relative humidity: 0% to 100%

Fast Delivery

Next-day shipping and scheduled deliveries available.

Finance Options

Our finance programs can make the transition smooth and affordable.

Get Help Buying

Have a question?
Call a specialist or message us today.
Call (301) 246-0151

BioOx Air Cleaning Systems are solving air quality challenges in industries around the world. To explore how you can achieve energy efficiency through air quality management, visit us at www.bioox.us, write to us at Air & Water Solutions, Inc., P.O. Box 627, Nutley, New Jersey 07110.